-40%
Knight-Ware Monolithic Stoneware Sump Basin Laboratory ACID BASE Resistant
$ 258.71
- Description
- Size Guide
Description
Excellent condition as shown. No cracks or damage. Finish on the inside still in very good shape.MODEL 400 & 401 KNIGHT-WARE® Monolithic Chemical Stoneware Sumps
GENERAL NOTES: CONSTRUCTION Using a very stiff clay mix, these ceramic shells, complete with connections and dip pipe, are formed in one piece, carefully dried, then vitrified at a kiln temperature in excess of 2100°F. The end product is a dense acid-proof stoneware vessel, completely joint-free and inert to all chemicals except hydrofluoric acid and hot concentrated caustic. FOUNDATION The 400 and 401 Series ceramic sumps should be bedded in a thin layer of sand or fresh stone-free grout on firm base. Avoid possibility of point bearings such as pebbles, rocks, or hard debris under bottom. When filled with neutralizing fill and water, the larger sumps involve considerable weight. Provide even load bearing when using beam supports; possibly using thin grout or roofing paper insulation.
MODEL 401 LOW CAPACITY 1-20 Student Stations Cover Style B – KNIGHT-WARE Flat-bolted Cover (12 x 12 only) BR– RESIBOND® Clamped Cover Cover for top inlet-side outlet (12x12 only) APPLICATION: Size 12" x 12" is suitable for installing in a laboratory cabinet under a sink. The Style BT may be connected to the sink drain without the need of an elbow. The sump may also serve as a trap when used with a single or two adjacent sinks. Sizes 18" x 24" and 24" x 36" sumps are installed to receive the waste from a collection system from a series of laboratory sinks. They are generally located in the building basement area or underground outside the building. If an extension is required to reach grade level for entrance to sump see Page 5. MODEL 400 MEDIUM CAPACITY 21 – 70 Student Stations Cover Style CR – RESIBOND® Clamped Cover APPLICATION These sumps are installed to receive the dilute acid wastes from a collection system from a series of laboratory sinks. They are generally located in a building basement area or underground outside the building. If an extension is required to reach grade level for entrance to sump, see Page 5. Size Approximate Neutralizing Student A B C D E F G H J Od Ship Weight Fill Stations 18 X 24 17 251 /2 271 /2 203 /4 21 /4 4 233 /4 21 300 lbs. 200 lbs. 2 to 6 24 X 36 28 371 /2 391 /2 281 /2 21 /2 4 313 /4 27 Size Approximate Neutralizing Student A B C D E F G H J Od Ship Weight Fill Stations 30 X 57 24 461 /2 491 /2 581 /2 601 /2 273 /4 4 33 1,200 lbs. 1,700 lbs. 21 to 40 36 X 70 30 59 62 713 /4 74 331 /2 6 391 /2 2,300 lbs. 3,200 lbs. 41 to 70